Kenton Modular Solo Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ekwipunek Kenton Modular Solo. Kenton Modular Solo User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 24
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
MODULAR SOLO
MODULAR SOLOMODULAR SOLO
MODULAR SOLO
MIDI-CV converter for Eurorack modular synths
Operating manual
Przeglądanie stron 0
1 2 3 4 5 6 ... 23 24

Podsumowanie treści

Strona 1 - MODULAR SOLOMODULAR SOLO

MODULAR SOLOMODULAR SOLOMODULAR SOLOMODULAR SOLO MIDI-CV converter for Eurorack modular synths Operating manual

Strona 2

10 P 34 Key-On resets LFO Wave (default :off) The following can be selected: Off [oFF] On [ on] - When on, the LFO waveform is reset to t

Strona 3 - CONNECTIONS

11 P 52 AUX 3 maximum value (default: 100) - Sets the level for the Auxiliary output when the MIDI controller source is at its maximum. Range

Strona 4 - EDITING THE MODULAR SOLO

12 P 71 Clock1 divide ratio - (default: d2) available values c24, c48 & d2 to d24, - sets the ratio of MIDI clocks to output pulses from the

Strona 5 - PARAMETERS

13 P 81 Clock2 divide ratio - (default: d2) - Sets the ratio of MIDI clocks to output pulses from the Clock2 output. available values d2 to d24

Strona 6

14 P 93 Prog receive enable - (default: Off) - Sets the function of the MIDI Out socket. The following can be selected: MIDI Out/Thru [MO] Syn

Strona 7 - AUX1 output

15 It may be that your synth is slightly out of tune, so it will be necessary to adjust the MODULAR SOLO to compensate for the tuning of yo

Strona 8

16 MIDI analyser mode: The MODULAR SOLO has a built-in MIDI analyser function. This feature allows you to see what types of MIDI messages are being t

Strona 9 - LFO control

17 When using MIDI clock in conjunction with the MODULAR SOLO, please note the following. First, ensure that the MODULAR SOLO is actually receiv

Strona 10 - AUX3 output

18 MIDI-CV converters can have up to four different types of outputs used to control analogue synths, usually labelled CV, GATE, S-TR

Strona 11 - CLOCK1 output

19 Whether the tip or the ring is in or out is hard to say as Moogs seem to vary from synth to synth! – The Rogue however uses RING for inputs and T

Strona 12 - CLOCK2 output

2 Warning - DO NOT ADJUST THE TRIMMERS ON THE PC BOARD. These are for factory setup ONLY. All adjustments to scale and tuning are made using the

Strona 13 - Global Parameters

20 MODULAR SOLO MENU CV / GATE - 01 - MIDI receive channel 02 - multi trig 03 - note priority - recent/lo/hi 04 - pitchbend range semitones 05 - por

Strona 14

21 Controller Number Control Function Decimal Hex 0 00H Bank select MSB 1 01H Modulation wheel/lever 2 02H

Strona 15

22 The MODULAR SOLO can be controlled by SysEx (System Exclusive) messages in the following formats: The first five bytes of SysE

Strona 16

23 11 coarse tune / transpose 232 > 0 > 24 { 2 } 12 fine tune val 129 > 0 > 127 129>0 = -ve

Strona 17

24 Power Input Power is supplied by the power supply in the modular case Power consumption +ve supply 85mA max / -ve supply 3mA

Strona 18

3 MODULAR SOLO INTRODUCTION The MODULAR SOLO is designed for use in Eurorack (A100) modular systems. It is much more than just a MIDI to CV co

Strona 19

4 Switching On When the MODULAR SOLO is switched on, the words KENTON MODULAR SOLO scroll across the display, and the unit reverts to the settin

Strona 20 - MODULAR SOLO MENU

5 Below is a list of parameters available to edit. The letters in square brackets show [where applicable] what will be shown on the LED display.

Strona 21

6 P 06 Portamento time / rate (default :98) Range 1 to 127 - Sets the portamento (glide or slide) time. This can also be adjusted

Strona 22 - SYSEX CONTROL

7 P 13 Fine tune (default: 0) Range -127 to +127 (approximately a semitone each way – use P12 above if you need more) - Fine tunes the mono-s

Strona 23

8 P 22 AUX 1 maximum value (default: 100) Range -27 to +100 - Sets the level for the Auxiliary output when the MIDI controller source is at its

Strona 24 - WEEE DIRECTIVE

9 LFO control P 30 LFO rate / speed (default :116) [approx 6.25Hz] - Sets the speed of the LFO. Range approx 0.1Hz to 100Hz. Range 0 to 191

Komentarze do niniejszej Instrukcji

Brak uwag